Some agent types definition that were generic enough to be reused
everywhere, have been split from the initial grpc package.
This prevents from importing the entire protobuf package through
the grpc one, and prevents binaries such as kata-netmon to stay
in sync with the types definitions.
Fixes#856
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Introduce constants for the network model strings, so as to
avoid using the strings directly at multiple places.
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Introduce a new mode that uses tc filters to redirect traffic from
the network interface created by the network plugin to a
tap interface that we connect to the VM.
This mode will help support ipvlan as well.
Fixes#144
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Refactor these functions so differernt types of endpoints can use a unified
function to hotplug nics.
Fixes#731
Signed-off-by: Ruidong Cao <caoruidong@huawei.com>
Explicitly check for "veth" intergace type while creating a
veth endpoint. Error out for unsupported network interfaces.
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
As this really represents a veth pair rather than a generic
virtual interface, rename VirtualEndpoint to VethEndpoint.
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Sort endpoints by name to control the order in which
they are passed to the VM as the interface name inside
the VM depends on the order in which it is passed.
Long term we should come up with a more robust approach.
Fixes#785
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Macvtap interfaces require mac addresses to be unique even
though they may be in a separate namespace. Hence use a randomly
generate MAC address.
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Add support for macvlan driver by bridging it with a macvtap or
tap+bridge and moving the mac and ip address from the
macvlan to the bridged interface.
Fixes#162
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Because the network monitor will be listening to every event received
through the netlink socket, it will be notified everytime a new link
will be added/updated/modified in the network namespace it's running
into. The goal being to detect new interface added by Docker such as
a veth pair.
The problem is that kata-runtime will add other internal interfaces
when the network monitor will ask for the addition of the new veth
pair. And we need a way to ignore those new interfaces being created
as they relate to the veth pair that is being added. That's why, in
order to prevent from running into an infinite loop, virtcontainers
needs to tag the internal interfaces with the "kata" suffix so that
the network monitor will be able to ignore them.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Add `disable_vhost_net` option to enable or disable the use of
vhost_net. Vhost_net can improve network performance.
Signed-off-by: Ruidong Cao <caoruidong@huawei.com>
Instead of using a default queue size of 8 for macvtap fds,
use the number of CPUs on the guest as the queue size.
This is the recommended approach. This also shown better
performance results.
Fixes#680
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
This commit moves the network namespace creation out of virtcontainers
in order to anticipate the move of the OCI hooks to the CLI through a
follow up commit.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Since we removed the CNI implementation and that we agreed the network
should only be handled in a single way from virtcontainers, this patch
logically replace the "CNM" naming with "Default".
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The specific agent implementation kata_agent was defining a very
useful generic function that is now moved to the global file
network.go.
Fixes#629
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Add additional `context.Context` parameters and `struct` fields to allow
trace spans to be created by the `virtcontainers` internal functions,
objects and sub-packages.
Note that not every function is traced; we can add more traces as
desired.
Fixes#566.
Signed-off-by: James O. D. Hunt <james.o.hunt@intel.com>
When creating a device structure to be added to the hypervisor, make
sure that the device includes the vhost-user type. In particular,
for network devices, specificy VhostUserNet.
Fixes: #601
Signed-off-by: Eric Ernst <eric.ernst@intel.com>
Remove unsed variable, the variable is set just in one place, and
never is used again.
Fixes: #603
Signed-off-by: Jose Carlos Venegas Munoz <jose.carlos.venegas.munoz@intel.com>
We dont really call CNI from Kata, this is done by the CRI layer.
All of the CNI code is unused.
Fixes#567
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
Instead of continuing with the network setup, we should detect
if host network namespace was requested and error out early.
Fixes#499
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
The interface "VhostUserDevice" has duplicate functions and fields with
Device, so we can merge them into one interface and manage them with one
group of interfaces.
Signed-off-by: Wei Zhang <zhangwei555@huawei.com>
Fixes#50
Previously the devices are created with device manager and laterly
attached to hypervisor with "device.Attach()", this could work, but
there's no way to remember the reference count for every device, which
means if we plug one device to hypervisor twice, it's truly inserted
twice, but actually we only need to insert once but use it in many
places.
Use device manager as a consolidated entrypoint of device management can
give us a way to handle many "references" to single device, because it
can save all devices and remember it's use count.
Signed-off-by: Wei Zhang <zhangwei555@huawei.com>
This PR got merged while it had some issues with some shim processes
being left behind after k8s testing. And because those issues were
real issues introduced by this PR (not some random failures), now
the master branch is broken and new pull requests cannot get the
CI passing. That's the reason why this commit revert the changes
introduced by this PR so that we can fix the master branch.
Fixes#529
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The interface "VhostUserDevice" has duplicate functions and fields with
Device, so we can merge them into one interface and manage them with one
group of interfaces.
Signed-off-by: Wei Zhang <zhangwei555@huawei.com>
Fixes#50
Previously the devices are created with device manager and laterly
attached to hypervisor with "device.Attach()", this could work, but
there's no way to remember the reference count for every device, which
means if we plug one device to hypervisor twice, it's truly inserted
twice, but actually we only need to insert once but use it in many
places.
Use device manager as a consolidated entrypoint of device management can
give us a way to handle many "references" to single device, because it
can save all devices and remember it's use count.
Signed-off-by: Wei Zhang <zhangwei555@huawei.com>
Use pointer here since api.VhostUserDevice interface is implemented
by VhostUserNetDevice pointer.
Fixes#446
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
All calls to deleteNetNS were passing the "mounted" parameter as
true. So drop this parameter.
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
In case of physical network interfaces, we explicitly
pass through them to the VM. We need to bind them back to
the host driver when the sandbox is stopped, irrespective if
the network namespace has been created by virtcontainers or not.
Fixes#384
Signed-off-by: Archana Shinde <archana.m.shinde@intel.com>
* Move makeNameID() func to virtcontainers/utils file as it's a generic
function for making name and ID.
* Move bindDevicetoVFIO() and bindDevicetoHost() to vfio driver package.
Signed-off-by: Zhang Wei <zhangwei555@huawei.com>
Fixes#50
This is done for decoupling device management part from other parts.
It seperate device.go to several dirs and files:
```
virtcontainers/device
├── api
│ └── interface.go
├── config
│ └── config.go
├── drivers
│ ├── block.go
│ ├── generic.go
│ ├── utils.go
│ ├── vfio.go
│ ├── vhost_user_blk.go
│ ├── vhost_user.go
│ ├── vhost_user_net.go
│ └── vhost_user_scsi.go
└── manager
├── manager.go
└── utils.go
```
* `api` contains interface definition of device management, so upper level caller
should import and use the interface, and lower level should implement the interface.
it's bridge to device drivers and callers.
* `config` contains structed exported data.
* `drivers` contains specific device drivers including block, vfio and vhost user
devices.
* `manager` exposes an external management package with a `DeviceManager`.
Signed-off-by: Zhang Wei <zhangwei555@huawei.com>